P603S Pump features:
- The pump with integrated controller is easy to install. The all-in-one design of the pump includes the programmable controller, a pressure switch/transducer and a vent valve.
- The single-line system's design and layout is uncomplicated, making it easy to install and operate. A single mainline reduces material and installation costs.
- An additional pressure switch at the end of larger systems can be used for added pressure control to ensure correct lubrication.
- Lincoln single-line systems completely vent during the pause interval. As a result, they are suitable for fast separating lubricants.
- For rotating operation in wind turbines, the reservoir is equipped with a follower plate and stirring paddle - which also facilitates the usage of fast separating lubricants. For stationary operation, a stirring and fixed paddle is sufficient.
Benefits:
- Simple maintenance - easy to expand
- SE1 suction elements for used lubricant
- Increased profit and productivity
- Improved operating times; less costly downtime resulting from improper lubrication
- Lower costs for repairs and spare parts
|
|
P653S Pump Specifications:
- Incoming metering: 0.05 - 0.4 cm3/stroke
- Supply voltage: 12 VDC, 24 VDC, 100-240 VAC
- Programmable controller: Yes
- Visual low-level: yes
- Internal Transducer: yes
|
12/24 VDC |
AC Pumps |
Pump output |
0.73 cu. in./min (12 cm3/min) |
0.73 cu. in./min (12 cm3/min) |
Maximum working pressure |
4,350 psig (300 bar) / 3,480 psig (240 bar) |
4,350 psig (300 bar) / 3,480 psig (240 bar) |
Maximum current draw |
2 Amps |
2 Amps |
Steering paddle and follower |
Yes |
Yes |
Reservoir size, Liter |
4, 8, 10, 15, 20 |
4, 8, 10, 15, 20 |
RPM, Paddle (76F) |
18 |
18 |
Pressure switch at pump |
Yes |
Yes |
Transducer at pump |
Yes |
Yes |
Pressure switch/ End of line |
Yes |
Yes |
Transducer/ End of line |
Yes |
Yes |
PCB |
Yes |
Yes |
Separate Alarms, LL/ Proxy switch |
No |
Yes |
24.0 VDC input |
Yes |
Yes |
Switching power supply |
No |
Yes |
Connectors |
Bayonet style |
Bayonet style + Square type (AC) |
Data logger |
No |
No |
Remotely change lube frequency |
Yes |
Yes |
Count Control |
Yes |
Yes |
Ignition & Neutral switch |
Yes |
Yes |
Acknowledging Fault |
At pump/ External |
At pump/ External |
Manually lube switch |
Yes |
Yes |
Pump on LED, External |
Yes |
Yes |
Protection |
IP 6K9K |
IP 6K9K |
Temperature |
-40°C to +70°C |
-40°C to +70°C |
|
Model |
Description |
Power |
Size (L) |
Follower Plate |
645-41064-3 |
P603S-4XLF-3Z7-AC-2A7.16-S13-SE |
AC |
4 |
X |
645-41062-3 |
P603S-8XLF-3Z7-AC-2A7.16-S13-SE |
AC |
8 |
X |
645-41110-2 |
P603S-8XLBO-3Z7-AC-3A7.16-S12-SE |
AC |
8 |
|
645-41062-4 |
P603S-8XLBO-3Z7-AC-3A7.16-S19-SE |
AC |
8 |
|
645-41073-5 |
P603S-15XLF-3Z7-AC-2A7.16-S13-SE |
AC |
15 |
X |
645-41064-8 |
P603S-4XLF1-3Z7-12-1A7.16-S01-SE |
12 DC |
4 |
X(Bayonet) |
645-41064-7 |
P603S-4XNBO-3Z7-12-2A7.16-S01-SE |
12 DC |
4 |
|
645-41110-3 |
P603S-8XLF1-3Z7-12-1A7.16-S01-SE |
12 DC |
8 |
X(Bayonet) |
645-41062-9 |
P603S-8XLF-3Z7-24-1A7.16-S01-SE |
24 DC |
8 |
X |
645-41064-4 |
P603S-4XLBO-3Z7-24-1A7.16-S17-SE |
24 DC |
4 |
|
645-41064-6 |
P603S-4XLF-3Z7-24-1A7.16-S13-SE |
24 DC |
4 |
X |
645-41064-2 |
P603S-4XNBO-3Z7-24-1A7.16-S01-SE |
24 DC |
4 |
|
645-41062-8 |
P603S-8XLBO-3Z7-24-2A7.16-S19-SE |
24 DC |
8 |
|
645-41062-9 |
P603S-8XLF-3Z7-24-1A7.16-S01-SE |
24 DC |
8 |
X |
645-41062-7 |
P603S-8XLF-3Z7-24-1A7.16-S03-SE |
24 DC |
8 |
X |
645-41119-1 |
P603S-10XLF-3Z7-24-1A7.16-S13-SE |
24 DC |
10 |
X |
645-41175-5 |
P603S-4XNBO-3Z7-12-1A7.16-S22-SE |
12 DC |
4 |
|
645--41119-2 |
P603S-10XLF-3Z7-AC-2A1.01-S13-SE |
AC |
10 |
X |