P603S Pump features:

  • The pump with integrated controller is easy to install. The all-in-one design of the pump includes the programmable controller, a pressure switch/transducer and a vent valve.
  • The single-line system's design and layout is uncomplicated, making it easy to install and operate. A single mainline reduces material and installation costs.
  • An additional pressure switch at the end of larger systems can be used for added pressure control to ensure correct lubrication.
  • Lincoln single-line systems completely vent during the pause interval. As a result, they are suitable for fast separating lubricants.
  • For rotating operation in wind turbines, the reservoir is equipped with a follower plate and stirring paddle - which also facilitates the usage of fast separating lubricants. For stationary operation, a stirring and fixed paddle is sufficient.

Benefits:

  • Simple maintenance - easy to expand
  • SE1 suction elements for used lubricant
  • Increased profit and productivity
  • Improved operating times; less costly downtime resulting from improper lubrication
  • Lower costs for repairs and spare parts
P603S 

P653S Pump Specifications:

  • Incoming metering: 0.05 - 0.4 cm3/stroke
  • Supply voltage: 12 VDC, 24 VDC, 100-240 VAC
  • Programmable controller: Yes
  • Visual low-level: yes
  • Internal Transducer: yes
Pump output 0.73 cu. in./min (12 cm3/min) 0.73 cu. in./min (12 cm3/min)
Maximum working pressure 4,350 psig (300 bar) / 3,480 psig (240 bar) 4,350 psig (300 bar) / 3,480 psig (240 bar)
Maximum current draw 2 Amps 2 Amps
Steering paddle and follower Yes Yes
Reservoir size, Liter 4, 8, 10, 15, 20 4, 8, 10, 15, 20
RPM, Paddle (76F) 18 18
Pressure switch at pump Yes Yes
Transducer at pump Yes Yes
Pressure switch/ End of line Yes Yes
Transducer/ End of line Yes Yes
PCB Yes Yes
Separate Alarms, LL/ Proxy switch No Yes
24.0 VDC input Yes Yes
Switching power supply No Yes
Connectors Bayonet style Bayonet style + Square type (AC)
Data logger No No
Remotely change lube frequency Yes Yes
Count Control Yes Yes
Ignition & Neutral switch Yes Yes
Acknowledging Fault At pump/ External At pump/ External
Manually lube switch Yes Yes
Pump on LED, External Yes Yes
Protection IP 6K9K IP 6K9K
Temperature -40°C to +70°C -40°C to +70°C
645-41064-3 P603S-4XLF-3Z7-AC-2A7.16-S13-SE AC 4 X
645-41062-3 P603S-8XLF-3Z7-AC-2A7.16-S13-SE AC 8 X
645-41110-2 P603S-8XLBO-3Z7-AC-3A7.16-S12-SE AC 8     
645-41062-4 P603S-8XLBO-3Z7-AC-3A7.16-S19-SE AC 8     
645-41073-5 P603S-15XLF-3Z7-AC-2A7.16-S13-SE AC 15 X
645-41064-8 P603S-4XLF1-3Z7-12-1A7.16-S01-SE 12 DC 4 X(Bayonet)
645-41064-7 P603S-4XNBO-3Z7-12-2A7.16-S01-SE 12 DC 4     
645-41110-3 P603S-8XLF1-3Z7-12-1A7.16-S01-SE 12 DC 8 X(Bayonet)
645-41062-9 P603S-8XLF-3Z7-24-1A7.16-S01-SE 24 DC 8 X
645-41064-4 P603S-4XLBO-3Z7-24-1A7.16-S17-SE 24 DC 4     
645-41064-6 P603S-4XLF-3Z7-24-1A7.16-S13-SE 24 DC 4 X
645-41064-2 P603S-4XNBO-3Z7-24-1A7.16-S01-SE 24 DC 4     
645-41062-8 P603S-8XLBO-3Z7-24-2A7.16-S19-SE 24 DC 8     
645-41062-9 P603S-8XLF-3Z7-24-1A7.16-S01-SE 24 DC 8 X
645-41062-7 P603S-8XLF-3Z7-24-1A7.16-S03-SE 24 DC 8 X
645-41119-1 P603S-10XLF-3Z7-24-1A7.16-S13-SE 24 DC 10 X
645-41175-5 P603S-4XNBO-3Z7-12-1A7.16-S22-SE 12 DC 4     
645--41119-2 P603S-10XLF-3Z7-AC-2A1.01-S13-SE AC 10 X