| P603S Pump features: 
The pump with integrated controller is easy to install. The all-in-one design of the pump includes the programmable controller, a pressure switch/transducer and a vent valve.The single-line system's design and layout is uncomplicated, making it easy to install and operate. A single mainline reduces material and installation costs.An additional pressure switch at the end of larger systems can be used for added pressure control to ensure correct lubrication.Lincoln single-line systems completely vent during the pause interval. As a result, they are suitable for fast separating lubricants.For rotating operation in wind turbines, the reservoir is equipped with a follower plate and stirring paddle - which also facilitates the usage of fast separating lubricants. For stationary operation, a stirring and fixed paddle is sufficient. Benefits: 
Simple maintenance - easy to expandSE1 suction elements for used lubricantIncreased profit and productivityImproved operating times; less costly downtime resulting from improper lubricationLower costs for repairs and spare parts |   | 
P653S Pump Specifications:
- Incoming metering: 0.05 - 0.4 cm3/stroke
- Supply voltage: 12 VDC, 24 VDC, 100-240 VAC
- Programmable controller: Yes
- Visual low-level: yes
- Internal Transducer: yes
| 
|  | 12/24 VDC | AC Pumps |  
| Pump output | 0.73 cu. in./min (12 cm3/min) | 0.73 cu. in./min (12 cm3/min) |  
| Maximum working pressure | 4,350 psig (300 bar) / 3,480 psig (240 bar) | 4,350 psig (300 bar) / 3,480 psig (240 bar) |  
| Maximum current draw | 2 Amps | 2 Amps |  
| Steering paddle and follower | Yes | Yes |  
| Reservoir size, Liter | 4, 8, 10, 15, 20 | 4, 8, 10, 15, 20 |  
| RPM, Paddle (76F) | 18 | 18 |  
| Pressure switch at pump | Yes | Yes |  
| Transducer at pump | Yes | Yes |  
| Pressure switch/ End of line | Yes | Yes |  
| Transducer/ End of line | Yes | Yes |  
| PCB | Yes | Yes |  
| Separate Alarms, LL/ Proxy switch | No | Yes |  
| 24.0 VDC input | Yes | Yes |  
| Switching power supply | No | Yes |  
| Connectors | Bayonet style | Bayonet style + Square type (AC) |  
| Data logger | No | No |  
| Remotely change lube frequency | Yes | Yes |  
| Count Control | Yes | Yes |  
| Ignition & Neutral switch | Yes | Yes |  
| Acknowledging Fault | At pump/ External | At pump/ External |  
| Manually lube switch | Yes | Yes |  
| Pump on LED, External | Yes | Yes |  
| Protection | IP 6K9K | IP 6K9K |  
| Temperature | -40°C to +70°C | -40°C to +70°C |  | 
| Model | Description | Power | Size (L) | Follower Plate | 
| 645-41064-3 | P603S-4XLF-3Z7-AC-2A7.16-S13-SE | AC | 4 | X | 
| 645-41062-3 | P603S-8XLF-3Z7-AC-2A7.16-S13-SE | AC | 8 | X | 
| 645-41110-2 | P603S-8XLBO-3Z7-AC-3A7.16-S12-SE | AC | 8 |  | 
| 645-41062-4 | P603S-8XLBO-3Z7-AC-3A7.16-S19-SE | AC | 8 |  | 
| 645-41073-5 | P603S-15XLF-3Z7-AC-2A7.16-S13-SE | AC | 15 | X | 
| 645-41064-8 | P603S-4XLF1-3Z7-12-1A7.16-S01-SE | 12 DC | 4 | X(Bayonet) | 
| 645-41064-7 | P603S-4XNBO-3Z7-12-2A7.16-S01-SE | 12 DC | 4 |  | 
| 645-41110-3 | P603S-8XLF1-3Z7-12-1A7.16-S01-SE | 12 DC | 8 | X(Bayonet) | 
| 645-41062-9 | P603S-8XLF-3Z7-24-1A7.16-S01-SE | 24 DC | 8 | X | 
| 645-41064-4 | P603S-4XLBO-3Z7-24-1A7.16-S17-SE | 24 DC | 4 |  | 
| 645-41064-6 | P603S-4XLF-3Z7-24-1A7.16-S13-SE | 24 DC | 4 | X | 
| 645-41064-2 | P603S-4XNBO-3Z7-24-1A7.16-S01-SE | 24 DC | 4 |  | 
| 645-41062-8 | P603S-8XLBO-3Z7-24-2A7.16-S19-SE | 24 DC | 8 |  | 
| 645-41062-9 | P603S-8XLF-3Z7-24-1A7.16-S01-SE | 24 DC | 8 | X | 
| 645-41062-7 | P603S-8XLF-3Z7-24-1A7.16-S03-SE | 24 DC | 8 | X | 
| 645-41119-1 | P603S-10XLF-3Z7-24-1A7.16-S13-SE | 24 DC | 10 | X | 
| 645-41175-5 | P603S-4XNBO-3Z7-12-1A7.16-S22-SE | 12 DC | 4 |  | 
| 645--41119-2 | P603S-10XLF-3Z7-AC-2A1.01-S13-SE | AC | 10 | X |