Model 1849

Fully automatic assembly including pump, 220/240 volt motor, translucent reservoir with spring-loaded follower, 4000 psi (276 bar) safety unloader, adjustable pressure switch and time control. Time control is adjustable for lubrication cycle frequency of 5, 10, 15, 20, 30 or 60 min. Solid state time delay relay (35 sec. to 240 sec.) included for connection of audible or visual alarm to signal lubrication failure due to empty reservoir or broken supply line. See Model 85520 in Systems Control section for controller specifications.

Electrical Specifications Pump Motor 220/240 VAC, 60 Hz, 3 ph
Controller  115 VAC, 60 Hz
Lube Outlet 1/4 in. NPTF(F)
Filling Method 81834 Filler pump or Manual Pump and 645006 Coupler
Typical System Operating Pressure  Min. 1200 psig (82 bar)
 Max. 3500 psig (241 bar)
Reservoir Capacity 12 lb. (5.44 kg) / 360 cu. in. (5900 cc)
Dimensions (LxWxH) 25-3/8" x 13" x 19-13/16" (645 x 330 x 503 mm)
1849 

Model 201849

Same as Model 1849 except has 7 lb. reservoir capacity.

Model 1835

Same as Model 1849 except has 115 VAC, 60 Hz motor and controller.

Model 1833

Similar to Model 1849 except:

  • 24 VDC pump motor and controller
  • Metal reservoir with visual level indicator rod
  • 2.5, 5, 10, 20, 40, and 80 minute cycle frequency adjustment
  • 60 second fixed on time and alarm relay features
  • Incorporates pressure switch factory st at 2500 psi (172 bar)
Electrical Specifications Pump Motor 1/4 HP, 24 VDC, 10 AMP
Controller 24 VDC, 5 watts
Lube Outlet 1/4 in. NPTF(F)
Filling Method 81834 Filler pump or Manual Pump and 645006 Coupler
Typical System Operating Pressure  Min. 1200 psig (82 bar)
 Max. 3500 psig (241 bar)
Reservoir Capacity 12 lb. (5.44 kg) / 360 cu. in. (5900 cc)
Dimensions (LxWxH) 34-1/4" x 11-1/2" x 21-3/4" (870 x 292 x 552 mm)
 1833

Notes:

  • Controller has provision for remote manual lube button and remote lube failure alarm
  • Enclosure is designed to meet NEMA 3S and 12 specifications

Model 1812

Pump has translucent reservoir with filler cap and strainer. Pump base has built-in check/vent valve and an indicator pin to show when system pressure is achieved.

Reservoir Capacity 4-1/2 pint / 130 cu. in. (2.13 L/ 2130cc)
Lube Outlet 1/4 in. NPTF(F)
Typical System Operating Pressure  Min. 750 psig (52 bar)
 Max. 1000 psig (69 bar)
Dimensions 16-3/4" x 7-1/8" x 7-3/4" (425 x 181 x 197 mm)
 1833